HawkRaman Raman System


  • Lamp-Source» Portable

    This portable Raman System is under 2.5 Kgs. Designed wil-meter fi cpled Raman Probe. System is developed to keep in mind ease and portability with no compromise in measuring capabilities. it has 7-inch-wide touch screen.

    Sl No.ParametersHawk Raman Portable
    1Excitation Laser532nm* - 785nm*
    2Laser power350,500mW
    3Resolution

    6-12cm-1

    4Range

    100cm-1 - 3200cm-1

    5Detector typeCCD/CMOS
    6CooledNO
    7Computer InterfaceUSB2.0
    8CameraOptional
    9Inbuilt BatteryBackup Upto 2.5hrs*
    10Weight<2.5 Kgs
    11Operating temp0-40°C

  • Lamp-Source» Handheld

    A field-ready invaluable identification tool weighing only 800 gms. Designed for very quick check and forensic analysis by safety personal and first responders including Law enforcement personnel, Bomb squads, Customs and Border Patrol.

    Sl No.ParametersHawk Raman Handheld
    1Excitation Laser785nm*
    2Laser power500mW
    3Resolution

    8-12cm-1

    4Range

    100cm-1 - 2800cm-1

    5Detector typeCCD
    6CooledNO
    7Computer InterfaceUSB2.0
    8CameraYES
    9Inbuilt BatteryBackup Upto 2.5hrs*
    10Weight<0.8 Kgs
    11Operating temp0-40°C

  • Solar-simulator» Microscopic

    The Hawk Raman Micro System is designed keeping in mind the users that are interested in micron level spatial resolution of their raman sample.This system can provide analysis on very small feature of their sample. To align the sample, manual XYZ Translation stage along with sample viewing camera is provided for measurement. The Hawk Raman Micro has an option to couple research grade microscope objective from 10X to 100X as per user requirement.

    Sl No.ParametersHawk Raman Microscopic
    1
    Excitation Laser532nm* 785nm*
    2Laser power350,500mW
    3Resolution

    6-12cm-1

    4Range

    100cm-1 - 3200cm-1

    5Detector typeCCD/CMOS
    6CooledNO
    7Computer InterfaceUSB2.0
    8CameraYES
    9Inbuilt BatteryOptional
    10Weight<6 Kgs
    11Operating temp0-40°C

     

  • Fiber-coupled-source» TE-Cooled

    We are offering TEC Raman for demanding applications like Pharmaceutical analysis of samples where higher exposure time are required, a cooled sensor (Δ65°C) helps in giving excellent signal to noise ratio making it possible to measure even the slightest Raman signals and detect subtle sample differences.

    Sl No.ParametersHawk Raman Cooled
    1Excitation Laser532nm* - 785nm*
    2Laser power350,500mW
    3Resolution

    6-12cm-1

    4Range

    100cm-1 - 3200cm-1

    5Detector typeCCD/CMOS
    6CooledYES (Δ65°C)
    7Computer InterfaceUSB2.0
    8CameraOptional
    9Inbuilt BatteryOptional
    10Weight<8 Kgs
    11Operating temp0-40°C
  • Microfocus-X-ray-source» Free Space

    For applications where sample is not in direct access and user wants to conduct identification in free space. This system has a detection range of 30 cm* and weighs under 5 Kgs.

    Sl No.ParametersHawk Raman Free Space
    1Excitation Laser532nm*
    2Laser power500mW
    3Resolution

    6-12cm-1

    4Range

    100cm-1 - 2800cm-1

    5Detector typeCCD/CMOS
    6CooledNO
    7Computer InterfaceUSB2.0
    8CameraOptional
    9Inbuilt BatteryBackup Upto 2.5hrs*
    10Weight<5 Kgs
    11Operating temp0-40°C
  • UV-LED-based-sources» Stage

    Options of xy, xz or xyz multi-axis motion configurations. We combines our precision linear adjustment screws and micrometer actuators with advanced bearing configurations and precision machined surfaces to create the manual linear stages required by top researchers.



    UV-LED-based-sources» Liquid Sample Holder

    The sample holder accommodate and cuvettes. Making it easy to load and unload samples, block ambient light, and improve the accuracy of Raman measurements. It also has a positioning screw to optimize the focus of the laser onto the sample.



    UV-LED-based-sources» Direct Contact Attachment

    Direct contact attachment for raman probe regulates the distance and the angle between the probe and your sample so that you get a consistent measurement every time. This is ideal for measuring various points on large samples due to its small size and ease of use.



    UV-LED-based-sources» SERS Substrate

    SERS (Surface Enhanced Raman Scattering) technique is known to be a powerful method for chemical and biological sensing applications.SERS substrates offer excellent reproducibility and significant enhancement allowing detection of molecules which otherwise could not be detected using classical Raman spectroscopy, and easier/faster analysis of weak Raman scatterers.



    UV-LED-based-sources» Raman Probe

    Our Raman probes are versatile sampling accessories . The probes are available with FC and SMA connectors for excitation and collection fibers. Raman probes are anodized aluminum with a stainless steel tip and has an option to include a manual safety shutter. These are non-immersion probes that are ideal for measurement of solids and surfaces and for measurement through glass and plastics



    UV-LED-based-sources» Raman Microscope

    It is a reliable and easy-to-use point-and-shoot instrument providing research-grade results with user-changeable Microscope Objective upto X100.